The easYgen-3200XT combines complete engine-generator control and protection with advanced, peer-to-peer paralleling functionality and innovative features in a robust, attractive and user-friendly package.
SPECIFICATIONS
Power supply ...........................................................12/24 VDC (8 to 40 VDC)
Intrinsic consumption ........................................ max. 14 W (LT: max.22W)
Ambient temperature (operation) ................ -20 to 70 °C (LT: -40 to 70 °C)
Ambient temperature (storage) ........................ -30 to 80 °C / -22 to 176 °F
Ambient humidity....................................................... 95%, non-condensing
Voltage (software configurable) ..................................................... ( /)
100 Vac Rated (Vrated) ............................................ 69/120 VAC
Max. value (Vmax) ............................................ 86/150 VAC
and 400 Vac Rated (Vrated) .......................................... 277/480 VAC
Max. value (Vmax) .......................................... 346/600 VAC
Rated surge volt. (Vsurge) .................................................... 4.0 kV
Accuracy ....................................................................................... Class 0.5
Measurable alternator windings ... 3p-3w, 3p-4w, 3p-4w OD, 1p-2w, 1p-3w
Setting range ..................... primary ................................. 50 to 650,000 VAC
Linear measuring range .............................................................. 1.25×Vrated
Measuring frequency............................................... 50/60 Hz (40 to 85 Hz)
High Impedance Input; Resistance per path ................................... 2.0 M
Max. power consumption per path ................................................ < 0.15 W
Current (Isolated, software configurable) Rated (Irated) ......... 1A or 5A
Linear measuring range ........................................................ Igen = 3.0×Irated
Imains/ground = 1.5×Irated
Setting range .......................................................................... 1 to 32,000 A
Burden .......................................................................................... < 0.10 VA
Rated short-time overcurrent (1 s) ..........................[1] 50×Irated, [5] 10×Irated
Accuracy ...................................................................................... Class 0.5
Power .........................................................................................................
Setting range .......................................................... 0.5 to 99,999.9 kW/kvar
Accuracy ....................................................................................... Class 1.0
Discrete inputs .............................................................................. isolated
Input range ..............................................................12/24 VDC (8 to 40 VDC)
Input resistance .............................................................. approx. 20 kOhms
Relay outputs .................................................................................... isolated
Contact material ................................................................................... AgCdO
Load (GP) ......................................................................... 2.00 AAC@250 VAC
2.00 ADC@24 VDC / 0.36 ADC@125 VDC / 0.18 ADC@250 VDC
Analog inputs (isolated) .........................................................freely scalable
Type .................................................... 0 to 1V / 0 to 2000 Ohms / 0 to 20 mA
Resolution .............................................................................................. 16 Bit
Analog outputs (isolated) ......................................................freely scalable
Type ......................................................................... ± 10 V / ± 20 mA / PWM
Insulation voltage (continuously, AVR out) ......................................... 300 VAC
Insulation voltage (continuously, Gov out) .......................................... 100 VAC
Resolution .............................................................................................. 12 Bit
± 10 V (scalable) ............................................................... internal resistance
± 20 mA (scalable) ................................................ maximum load 500 Ohms
Housing Front panel flush mounting ...................................... Plastic housing
Dimensions WxHxD .......................................... 282 × 216 × 96 mm
Front cutout WxH .................................. 249 [+1.1] × 183 [+1.0] mm
Connection ....................................................... screw/plug terminals 2.5 mm²
Front .................................................................................... insulating surface
Sealing Front .................................. IP66 (with screw fastening)
Front .................................. IP54 (with clamp fastening)
Back ...................................................................... IP20
Weight .................................................................................... approx. 1,850 g
Housing Back panel mounting ............. Powder Coated Sheet metal housing
Dimensions WxHxD .......................................... 250 × 227 × 50 mm
Connection ....................................................... screw/plug terminals 2.5 mm²
Protection system ................................................................................... IP 20
Weight .................................................................................... approx. 2,150 g
Disturbance test (CE) ............ tested according to applicable IEC standards
Listings (Pending) .................................... CE, UL, CSA, EAC, BDEW, VDE
Marine (Pending) ........................ LR (Type Approval), ABS (Type Approv